Bulk density calibration for X-ray tomographic analyses of marine sediments
Orsi, T.H.; Anderson, A.L. (1999). Bulk density calibration for X-ray tomographic analyses of marine sediments. Geo-Mar. Lett. 19(4): 270-274. https://dx.doi.org/10.1007/s003670050118
In: Geo-Marine Letters. Springer: Heidelberg; Berlin. ISSN 0276-0460; e-ISSN 1432-1157, meer
Peer reviewed article  

Beschikbaar in  Auteurs 

Trefwoord
    Marien/Kust
Author keywords
    Bulk Density; Sediment Sample; Sediment Core; Marine Sediment; Density Profile

Auteurs  Top 
  • Orsi, T.H.
  • Anderson, A.L.

Abstract
    A calibration procedure is presented for generating bulk density profiles of intact marine sediment cores using X-ray computed tomography (CT). Developed using both artificial and natural marine sediment samples, the correlation is strong with an R2 value of 0.98. Similar experiments with carbonate sediments were also strongly linear, but offset from the terrigenous curve, illustrating the influence of sediment chemistry on scanner response. Comparison between newly computed densities for both sediment types with those from individually calibrated cores during our previous CT studies reveals good correspondence between the data sets.